Home > Wmi Error > Wmic Error

Wmic Error

Contents

When this code is encountered PDQ Deploy will interpret the code to mean SUCCESS. You can select alternate WMI namespaces from the drop-down list as a way to browse through the entire WMI Repository and see if the class can be found.If the class exists For example, this script tries to connect to the root\cim2v namespace; because there is no such namespace, the script fails with an 0x8004100E error: Copy strComputer = "." Set objWMIService = Join them; it only takes a minute: Sign up WMIC Product GET Name - Invalid Class up vote 0 down vote favorite I am trying to list all of the programs

You need to press F8 before the Windows logo appears. If the connection fails you will get an “Invalid class” error.I’m getting an error (0x800A01B6) that says a property or method is not supportedOn occasion you might run a script and What is the first text considered Italian instead of Latin? Show: Inherited Protected Print Export (0) Print Export (0) Share IN THIS ARTICLE Is this page helpful?

Wmi Error Invalid Class

WMI is a resilient piece of software. Notice, however, what happened after I changed the WMIC command in the batch file to specifically specify the target computer as the Domain value therein modifying only specified LOCAL user accounts. WMIC.exe returned the code -2147217407. Browse other questions tagged variables batch-file uninstall wmic or ask your own question.

  1. There is no 27a windows error or 0xc000027a NT Status code.
  2. By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks.
  3. Failures can originate in other parts of the operating system and emerge as errors through WMI.
  4. Use Safe Mode with Networking if you need internet access.
  5. Facility = WMI I'm trying to run this on a standard install of Windows Server 2003 R2 with administrator privelages.
  6. I believe recently installed software is preventing windows from booting up.
  7. Publish at very specific time Will applying twenty year old cow manure hurt my vegetable garden?
  8. Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you!
  9. Reboot.

This can include a query that is too complex, retrieving an instance, creating or updating a class, deleting a class, or enumerating a class. WBEM_E_CLASS_HAS_CHILDREN 2147749925 (0x80041025) Attempt was made This error usually applies to invalid attempts to delete classes or properties. WBEM_E_INVALID_QUERY 2147749911 (0x80041017) Query was not syntactically valid. WBEM_E_INVALID_QUERY_TYPE 2147749912 (0x80041018) Requested query language is not supported. This can be returned only when data is being stored in an SQL database. WBEM_E_DATABASE_VER_MISMATCH 2147750008 (0x80041078) The database version does not match the version that the repository driver processes. Failed To Initialize All Required Wmi Classes Either it is incomplete or it has not been registered with WMI using SWbemObject.Put_. WBEM_E_INVALID_SYNTAX 2147749921 (0x80041021) Query is syntactically not valid. WBEM_E_NONDECORATED_OBJECT 2147749922 (0x80041022) Reserved for future use.

Once I realized I could run it from the wbem directory, I checked my PATH variable and it didn't exist anymore. Wmi Return Codes What would be the disadvantage to defining a class as a subclass of a list of itself? The service can be stopped; however, it is designed to automatically restart any time you connect to a WMI namespace using a tool (such as Wbemtest.exe) or a WMI script.Although unlikely, https://msdn.microsoft.com/en-us/library/aa394559(v=vs.85).aspx Instead, the WMI service will probably just restart itself and run your script.

It should be #pragma DeleteInstance("instancepath", FAIL|NOFAIL) WBEMMOF_E_INVALID_QUALIFIER_SYNTAX 2147762221 (0x8004402D) The qualifier syntax is not valid. Failed To Connect To Wmi Namespace Root Cimv2 If neither the script nor the wbemtest work, then probably WMI is super hosed, and you'll have to repair it. have you a idea how to fix this on the pdq deploy site ?" Answer: PDQ Deploy returns the last error code that the Installation File returned. Untick everything left.

Wmi Return Codes

Why did Harry Potter behave like this to Lupin? learn this here now For example, you try to connect to a class named Win32_Services (with an s on the end) when the actual class name is Win32_Service (without an s on the end).You reference Wmi Error Invalid Class WMI Error Constants If an error occurs, WMI returns an error code as an HRESULT value. Win32_processor Wmi Invalid Class If the repair fails or if your script still does not work then you will need to contact Microsoft Product Support Services.Microsoft Windows XP, Service Pack 2If you are running Windows

Is it correct to say "I hurt"? For example, this script returns information about all the services named Alerter that are currently running: Copy strComputer = "." Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2") Set colItems = Am I interrupting my husband's parenting? I am also passing the %ComputerName% variable so that the domain is set to the target machine (and will, therefore, modify the Administrator account on the local computer as opposed to Wmi Invalid Namespace

In a company crossing multiple timezones, is it rude to send a co-worker a work email in the middle of the night? Use this: wmic path Win32_UserAccount where "Name='administrator' and Domain='%computername%'" set PasswordExpires=false Notice that since I have more than one filter in my WHERE clause I need to encapsulate them in double Change root\default to root\cimv2, then click Connect. Will the computer lock up?

asked 1 year ago viewed 1536 times active 13 days ago Blog Stack Overflow Podcast #93 - A Very Spolsky Halloween Special Linked 33 Configure custom SSL certificate for RDP on Wmi Return Value 9 WMI Return Codes This section provides a list of the WMI return codes, symbolic constants, literal values, and descriptions. Press Ctrl + Alt + Delete then Task Manager.

Join Now Hi guys, So im setting up my spiceworks installation and scanning our devices.  I have a few remote machines that fail the WMIC test to obtain their serial number. 

Tick Hide All Microsoft Services and untick everything that's left. I recently spent a bit of time troubleshooting WMI issues, so maybe a couple of those same techniques will work here. Yes No Do you like the page design? Wmi Error Windows 7 Troubleshooting Problems with WMI Scripts and the WMI Service Important Before you begin repairing suspected problems with the WMI service it is strongly recommended that you run the new WMI Diagnosis

After downloading and installing Scriptomatic, start the utility and wait for the WMI namespace information to load. What to write in visa application form and what documents to submit as a unregistered freelancer? Sometimes the simplest explanation is the best: if a computer is offline you won’t be able to connect to it using WMI (or using much of anything, for that matter). But it looks like WMI might be a bit hosed.

For more information, see Provider Hosting and Security. So to see it in a command prompt reg query HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall /s Also your error code seems invalid. Class names will be spelled out in the appropriate .MOF file because those files are responsible for adding information about classes to the WMI Repository.I have a script that I know This document (developed in conjunction with the WMI team at Microsoft) is designed to help you troubleshoot problems with WMI scripts and the WMI service.

A specific WMI operation failed because of An error in the request, for example, a WQL query fails or the account does not have the correct permissions. For example, suppose the WMI service is stopped, yet you still try running a WMI script. WMI Isn’t Working! If you type in something else, say, checkwmisetup, the consistency check will fail with the message “Missing entry: checkwmisetup”.After issuing this command, check the WMI Setup log (%windir%\System32\Wbem\Logs\Setup.log).

As a regular user (that is, a non-Administrator) you have limited ability to run WMI scripts on the local computer; typically you will be able to retrieve information using WMI but Under any circumstances, do not delete the WMI repository as a first action because deleting the repository can cause damage to the system or to installed applications. asked 2 years ago viewed 403 times active 2 years ago Blog Stack Overflow Podcast #93 - A Very Spolsky Halloween Special Related 0WMIC - bat file menu program1Batch Script: Merging You can, but there are some risks involved in wiping out and replacing the Repository.

Ctrl + Shift + Right click a blank spot (just above the power buttons is one place) then Exit Explorer. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed Have you thought about a simpler approach, like a batch file that does: rem Uninstall old program: msiexec /qb /x {05EC21B8-4593-3037-A781-A6B5AFFCB19D} rem Install new program: msiexec /qb /i MyNewProgram.msi (of course, You bet there is: if you are having problems with a WMI script, don’t jump to conclusions and assume that WMI is broken.

If you are running Windows XP or Windows Server 2003 the WMI service runs inside a process named Svchost; this process contains other services as well as WMI. I tried searching the web but couldn't find anything. The following list lists some common ranges of errors. 0x80041068 - 0x80041099 Errors that originate in WMI itself. Before doing so you should enable WMI’s verbose logging option.

Follow us