Home > Winsock Error > Winsock Error 0

Winsock Error 0

Contents

The Windows Sockets implementation documentation to be sure all necessary components are currently installed and configured correctly. WSA_QOS_ESDMODEOBJ 11029 Invalid QoS shape discard mode object. Microsoft C description: Bad file number. It may also indicate you are not closing the applications properly. Source

WinSock functions: recv(), recvfrom(), send(), sendto(), with datastream sockets only. That's about one-quarter of the error values that aren't even used! Conclusion If you have all the necessary information on your network, you can usually set up TCP/IP for Windows easily. Too many references to some kernel object.

Socket Error 10054

a TCP reset received from remote host). No process may have more than a system-defined number of file descriptors open at a time. WSAEPROTONOSUPPORT (10043) Protocol not supported. This normally results if the peer application on the remote host is suddenly stopped, the host is rebooted, the host or remote network interface is disabled, or the remote host uses

An application used a Windows Sockets function that directly maps to a Windows function. By calling shutdown a partial close of a socket is requested, which is a signal that sending or receiving, or both have been discontinued. the byte-order functions, htonl(), htons(), ntohl and ntohl(), cannot fail. Socket Error 10049 Do not set non-zero timeout on non-blocking sockets to avoid this ambiguity (see Chapter 9 for more information).

WSAEDQUOT 10069 Disk quota exceeded. VB Code: Private Sub wskClientConnector_Connect() wskClientConnector.SendData "USER " & txtUsername.TextEnd Sub Last edited by hothead; Mar 6th, 2004 at 06:10 AM. WSA_QOS_NO_SENDERS 11007 No QoS senders. http://www.sockets.com/err_lst1.htm The time now is 06:34 PM.

You can then repair the Winsock defected file. 7. Socket Error 10054 Connection Reset By Peer Developer suggestion: are you trying to use an optional feature? Each implementation may have a maximum number of socket handles available, either globally, per process, or per thread. This could happen with a call to another function later, including connect, listen, WSAConnect, or WSAJoinLeaf.

  1. WinSock functions: WSAENETDOWN (10050) Network is down.
  2. ping This will ping the host you are trying to reach by name.
  3. However, if problems do occur, you should contact your network administrator for help.
  4. No more results can be returned by the WSALookupServiceNext function.
  5. However, there's little distinction between WSAEALREADY and WSAEINVAL since a WinSock DLL cannot tell the difference between an asynchronous operation that has been cancelled and one that was never valid.
  6. WSA_QOS_TRAFFIC_CTRL_ERROR 11014 QoS traffic control error.
  7. WinSock functions: recv(), recvfrom(), send(), sendto() WSAENAMETOOLONG (10063) File name too long.
  8. TCP/IP scenario: Calling shutdown() with how=1 or how=2 sends a TCP FIN packet to the remote address, which literally means "I'm done sending." If the local host sent any more data
  9. However, some WinSocks fail with WSAEINVAL you call connect() a second time (or subsequent) on a non-blocking socket.
  10. You may opt for drivers update.

Winsock Error Windows 7

Try a "traceroute" to the host you were connected to. try here WinSock description: Similar to Berkeley & Microsoft C, the generic meaning is that an application passed invalid input parameter in a function call. Socket Error 10054 If you receive an error check the TCP/IP configuration, or you may have the wrong gateway for your subnet. Winsock Error 10053 This is handy if a network device will only allow so many hops to take place from one host to another, or you are trying to locate a problem on a

WinSock functions: WSAENOTSOCK (10038) Socket operation on non-socket. this contact form A system call that should never fail has failed. VB Code: Private Sub wskServerListener_ConnectionRequest(ByVal requestID As Long) wskServerListener.Close wskServerListener.Accept requestID rtbServerMessages.Text = rtbServerMessages.Text & "A client has connected" & vbNewLine ColorServerMessageLines If Not wskServerConnector.State = WinSock function: gethostbyaddr(), gethostbyname(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), WSAAsyncGetServByPort() See also: WSANO_DATA, WSANO_RECOVERY, WSATRY_AGAIN WSAVERNOTSUPPORTED (10092) WINSOCK.DLL version out of range Berkeley description: No equivalent. What Is A Socket Error

Berkeley description: Some invalid argument was supplied (for example, specifying an invalid level to the setsockopt() function). The occurrence of an unlisted error can provide extra detail. WSAEBADF (10009) Bad file descriptor. have a peek here A call to the WSALookupServiceEnd function was made while this call was still processing.

User suggestions: see WSAHOST_NOT_FOUND for details. Wsagetlasterror 0 Some of the types of things you will find under some errors are: Microsoft C description: the first few WinSock errors are carry-overs from the standard 'C' runtime library. This has no network-relevant analog (although the "inode" reference could refer to a network file system entry).

Bottom line: These are just few of the things you can do to fix Winsock error.

Specifically, these error-less functions are the byte order functions ( htonl(), htons(), ntohl(), and ntohs()), the address manipulation functions (inet_addr(), and inet_ntoa), WSAGetLastError() and WSAIsBlocking(). WSAENETDOWN 10050 Network is down. Developer suggestions: Always check the return value from a memory allocation to be sure it succeeded. Winsock Error 10061 Generically, the error means the network system has run out of socket handles.

An incorrect number of QoS FILTERSPECs were specified in the FLOWDESCRIPTOR. WinSock functions: accept(), bind(), connect(), listen(), send(), sendto(), socket(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), WSAAsyncGetServByPort(), FD_CONNECT Additional functions: Any other functions that use network system buffer space, like the "database functions", It also occurs with functions that take a socket handle and a sockaddr structure as input parameters. http://itechnologysolutionsllc.com/winsock-error/winsock-error-when.php The following list describes the possible error codes returned by the WSAGetLastError function.

Do you have a router configured? The WinSock API does not provide access to the Network File System application protocol, so this error is irrelevant to WinSock. An invalid shape discard mode object was found in the QoS provider-specific buffer. WinSock functions: WSAEWOULDBLOCK (10035) Resource temporarily unavailable.

So I enter the download information again and it begins to verify a few files. Also see if you can establish a connection with some other host, elsewhere on the network. Friday, July 24, 2009 5:26 PM 0 Sign in to vote AG,Unfortunately, had the condition occur today.  Let the machine sit overnight (it was working).  Came in today and checked the connection.  I The attempted operation is not supported for the type of object referenced.

WSA_QOS_EFILTERSTYLE 11019 Invalid QoS filter style. WSAELOOP 10062 Cannot translate name.

Follow us