Home > Error Code > Winhttp Error Code 12002

Winhttp Error Code 12002

Contents

If the post was helpful...Rate it! The problem is that it throws a 12002 Time Out after about a minute on both of my machines, and a majority of machines that I've tested it on. This function is ok BOOL CSslServer :: ParseClientPacket(SSL* ssl, BYTE** lpBuf, DWORD* dwTransCb) { char* lpHeader = NULL; BOOL bOk = FALSE; int nRet = 0; int nHeaderBufCb = 1024; int madarasz.miklos 0 3 Oct 2014 12:05 PM Sameproblem. have a peek at this web-site

And also never forget to mark the thread as [Resolved] when your problem is solved Reply With Quote September 6th, 2007,01:23 AM #5 dglienna View Profile View Forum Posts Visit Homepage Code: BUG: RequestTimeout = 0 Does Not Work Within ITC ID: Q189302 -------------------------------------------------------------------------------- The information in this article applies to: Microsoft Visual Basic Standard and Enterprise Editions for Windows, version 5.0 Attempting to connect to an invalid IP. L"GET" : L"POST", (LPTSTR)lpReqObjName, L"HTTP/1.1", WINHTTP_NO_REFERER, WINHTTP_DEFAULT_ACCEPT_TYPES, WINHTTP_FLAG_SECURE))) __leave; // set cert options if (m_lpConfig->bSsl) { dwOptionCode = SECURITY_FLAG_IGNORE_CERT_CN_INVALID | SECURITY_FLAG_IGNORE_UNKNOWN_CA; if (!WinHttpSetOption(m_hRequest, WINHTTP_OPTION_SECURITY_FLAGS, &dwOptionCode, sizeof(DWORD))) __leave; } // all done https://msdn.microsoft.com/en-us/library/windows/desktop/aa383770(v=vs.85).aspx

Http Error 12002

GENERAL_SET_REQUEST_HEADER HeaderName="X-ARR-SSL", HeaderValue="", Replace="true" 16:50:21.033 81. This is typically a string or buffer containing a verbose error message. Only the ARR server is reporting a timeout, so that is where we should look first.

  1. Jun 14, 2012,04:44 AM #9 g3kko View Profile View Forum Posts Private Message View Articles View Gallery Uploads Rappy Hunter Join Date Sep 2010 Location germany Posts 13 i needed more
  2. CAUSE According to the documentation, setting timeout to 0 means infinity.
  3. Code: Visual InterDev Link View Error Messages When verifying links, Link View frequently interacts with WinInet.dll, the same DLL that Microsoft® Internet Explorer uses for Internet access.
  4. All rights reserved.

I also suggest you to try disabling your firewall and your antivirus software, I did so. Reply With Quote September 6th, 2007,03:14 PM #9 PeejAvery View Profile View Forum Posts Super Moderator Power Poster Join Date May 2002 Posts 10,939 Re: 12002 - Timeout Error The times To start viewing messages, select the forum that you want to visit from the selection below. Error Code 12019 This is a lesson.

With this information you could now start an investigation into why the Connection: close header was sent. 12002 Error_internet_timeout You can decode the error code with a tool like err.exe. The first thing we can see in the failed request trace log is where the request was sent to in the ARR_SERVER_ROUTED event. hop over to this website David CodeGuru Article: Bound Controls are Evil-VB6 2013 Samples: MS CODE Samples CodeGuru Reviewer 2006 Dell CSP 2006, 2007 & 2008 MVP Visual Basic If your question has been answered

If you are able to reproduce the error by browsing the web farm from the controller, and detailed errors are enabled on the server, you may see an error similar to Winhttp Error 12029 Reply With Quote September 5th, 2007,11:53 PM #4 chunks View Profile View Forum Posts Member Join Date Aug 2007 Posts 445 Re: 12002 - Timeout Error 5. It worked for a week or so, stopped for two days, and then worked once since then. Jun 14, 2012,02:57 AM #7 Mike View Profile View Forum Posts Private Message Visit Homepage View Articles View Gallery Uploads [゚д゚] < ナカソネティーチャー Join Date Feb 2001 Location Not the Satellite

12002 Error_internet_timeout

In the following example there is a directory called "time" which is configured with a simple aspx page as the default document of that directory. http://askville.amazon.com/Error-status-code-%2312002-correct/AnswerViewer.do?requestId=51620322 Are there different versions of required DLLs installed on the different machines? Http Error 12002 SendTimeout: If sending a request takes longer than this time-out value, the send operation is canceled. Wininet Error Codes It doesn't seem to be getting any data, but uses a lot of CPU bandwith, and no Network Activity while it runs.

Securing a LAN that has multiple exposed external Cat 6 cable runs? Check This Out This results in the 0x80072f78 error code being returned. We investigate this a bit further by enabling Failed Request Tracing on the IIS server. Sending too large of information packets. Winhttp Error 12175

Figure 4 (Click image to expand) The first step is to verify that the member servers are actually online. Other possible reasons for ERROR_WINHTTP_TIMEOUT include: ResolveTimeout: This occurs if name resolution takes longer than the specified timeout period. WinHTTP Error:12002 [No.103] Anyone know how to resolve it or if it's supposed to happen? -Wayu Jun 14, 2012,02:32 AM #2 Revlis-Desilver View Profile View Forum Posts Private Message Visit Homepage http://itechnologysolutionsllc.com/error-code/winhttpreceiveresponse-failed-with-error-code-12002.php HTTP/1.1 16060 3711.9 .98 .23 SSLv3 83 [SSL segment of a ressembled PDU] It takes me really a long time to solve this problem.

ReceiveTimeout: If a response takes longer than this time-out value, the request is canceled. Error Code 12029 Fix I really hope someone and handle this. There are three options of what it could be... 1.

Never gets COMPLETED.

The 10'000 year skyscraper Equal pay for equal work is controversial? Advanced Search Forum Visual Basic Programming Visual Basic 6.0 Programming [RESOLVED] 12002 - Timeout Error If this is your first visit, be sure to check out the FAQ by clicking the For example, if you receive this error when attempting to activatea GlobalSCAPEproduct, the error can indicate that communication with the activation server has not been established.This can be caused by a Error_winhttp_timeout Three locations.

To test this type of problem, create a simple .aspx page that calls Response.Close(). NO. What exactly timed-out? have a peek here I don't know what the Internet Transfer Control is so I don't actually know what you're trying to achieve. ● Tutorials: Home & Learn | Start VB.NET | Learn VB.NET |

Follow us