Home > Error Code > Vita Spa Flo Error Code

Vita Spa Flo Error Code

Contents

Spa has shut down. Sn2 = Nonfunctional temperature sensor. None of the pumps work now - only the blower.poolguy810 : okay, one thing to check on the plugs, if they plug into the outside of the box, open the box Posts: Popular In-ground Pool Heaters: Electric vs. this contact form

Do not enter the spa. I replaced the temp sensors but still get the error. let me know about this info and i can tell you what we need to tryCustomer: Jeff, It's hard to get to because it's behind the main electrical box but I HL = High limit switch tripped.

Vita Spa Flashing Flo

admin October 10, 2015 at 7:32 pm HI Ian,It sounds like the pump is air locked.You can check out this blog post here for more info on that: http://precisionpool.net/2010/10/how-to-release-an-air-lock-in-your-spa/-Jay admin October One sensor has detected 118º F at heater. To reset the spa, shut off the breaker for 5 sec. If you were to pull the back off of the marathon pump, you'll see three hot wires plus a ground wire.

This feature is not available right now. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F. Error & LCD Window Message Codes: ACC (Applied Computer Controls) CoLd = Temperature in the spa heater housing is below 40° F. How To Fix Flo Error Hot Tub If message comes back, call for service.

Wondering what your spa is trying to tell you? Vita Spa Error Codes at heater.OHS = Overheat. Scott Felsen 386 views 0:49 hot circ pump issue? - Duration: 3:46. 1NewUser4Me 2,963 views 3:46 FLO & FLC Error Codes | Arctic Spas Tutorial Video - Duration: 1:49.

My temp has been steady at 89, down from my usual 98.

Heater is shut down, but other spa functions run normally.dr = Inadequate water detected in heater.dry = Inadequate water detected in heater. (Displays on third occurrence of "dr" message). Marquis Spa Error Codes The low speed pump or circ pump will operate continuously until the temperature rises above 45° F. Remove the spa cover and let the water temperature cool down to 40°C (104°F). Heater is deactivated.F2 = 4 hours daily filtrationF4 = 8 hours daily filtrationF6 = 12 hours daily filtrationFC = continuous filtration EasyPak Control Systems for Spas or Hot Tubs: C =

  1. yes, that's the correct way to clean them is with filter cleaner and soaking, but if it's the filter causing the problem then the flo should go away if you remove
  2. The other pumps and the blower will purge for 30 seconds to 2 minutes at the end of the freeze condition.
  3. Remove the spa cover and allow the water to cool.
  4. SoftubSpasUK 5,854 views 8:21 FLO Error Code - Duration: 0:49.
  5. System will restart when temp.
  6. FLO2 = Closed or shorted flow switch on system startup Dream Maker Spa Side Error Codes OH = Overheat 108° F, spa is deactivated.
  7. Rare system error.

Vita Spa Error Codes

No LF or dry warnings. Shawn October 23, 2015 at 2:28 pm Hi. Vita Spa Flashing Flo Thanks, Rick poolguy810 and 2 other Pool and Spa Specialists are ready to help you Ask your own question now Customer: replied5 years ago. Vita Spa Pressure Switch th2/current temperature = On startup indicates temperature probe problem.

glad to hear, happy to help out, wish all solutions were that simple, have a great day, I'll send this rain your way tomorrow! Ask Your Own Pool and Spa weblink If you don't see them inside the control box, sometimes on the older packs they are in a fuse holder that is accessed from the outside of the control box that Spa has shut down. I am in no way adept in wiring/electrical repair. Hot Tub Error Codes

From here the troubleshooting takes you inside the spas service area and should be looked at by an experienced technician.Step 3.Check flow sensors or pressure switch to make sure they are There's no way your 3 hp single speed pump should be pushing water through the heater, it's too big and would go through the heater to fast to heat it much The Spa or Hot Tub Panel Displays: dr, dry This indicates that there is not enough water in the heater. http://itechnologysolutionsllc.com/error-code/winscp-general-failure-error-code-4-request-code-6.php Check water level in spa.

It looks like it is connected to the housing just to the right of the AO SMITH pump. Balboa Hot Tub Error Codes Something like this really requires a technician to come out and take a look. No action is necessary.PnL = Communication between the panel and circuit board is faulty.---- = "Watchdog" (spa is deactivated) A problem has been detected.Sn1 = Open sensor (heater is deactivated) or

Spa has shut down.

th2/current temperature = On startup indicates temperature probe problem. Heater is deactivated. Check for clogged filter.FL2 = Pressure switch problem. Artesian Spa Error Codes It automatically activates the pump (and the heater if necessary) to circulate the water and warm the plumbing.

Now one more thing the tub is 8 years old bUt last winter,Mn, I winterized it, mayBe screwed something up! If message comes back, call for service. Make sure that they are open.• Clean the filter(s), waterline skimmer and footwell suction for any blockage..• In extremely hot weather, check for proper cabinet ventilation.• Check for excessive filter duration. his comment is here Jeff, I found an honest guy to come fix the tub.

Heater disabled but the spa is operational.PSoC = Pressure switch open with circulating pump.PSoL = Pressure switch open with low pump.PSoH = Pressure switch open with high pump.ToE = Time out They are normally a time delay fuse that's either 25 or 30 amp. ICE = Freeze protection. balboawatergroup 14,815 views 4:17 Pressure switch - Duration: 1:25.

Heater is shut down, but other spa functions run normally. And on the pumps, yes, 2 speed pumps are always 4 wires, single speed pumps are always 3 wires, something isn't right there, but if nothing has been done to it If water level is not the problem you should remove the filter cartridges from the spa. admin June 7, 2016 at 8:53 am Hi Phil,If you hear the relay kicking but the pump is not engaging the motor could be shot.